Medical Supplies and Laboratory InstrumentOpen · stored

Purchase of Medical Equipment for medical services for the constituents of the City of Carcar

Buying agencyCITY OF CARCAR, CEBU

Bid Brief

Is this bid worth a closer look?

Stored notice data. Confirm all decisions with the official documents.

Open · storedCompany screening · Not checked
Approved budget₱5,000,000.00
Time remaining18 days leftDeadline Nov 18, 2026, 10:00 AM
Company screeningCompany screening has not been run for this bid.
Main thing to check
Company screening is not checkedCheck status
Why this matters

Relevance does not establish whether your company meets the bid requirements.

Next action
Check my company

Use the supporting sections below to verify the evidence.

Reference 13312100

Decision support

Company Screening

Compare stored requirements with evidence from this browser. Unknown answers stay as Needs verification.

How screening states work
GO No known blocker foundREVIEW More information requiredNO-GO Known conflict

Checking the stored deadline…

Not checked yet

Add only the evidence relevant to this bid, or screen with unknown answers.

Open full Your Company profile

Not assessed yet

Source-backed scope

What they’re buying

Stored category: Medical Supplies and Laboratory Instrument

Item No. Item Description QTY. Unit Unit Price Total Price PURCHASE OF MEDICAL EQUIPMENTS FOR SUPER HEALTH CENTER 1 Clinical Chemistry Analyzer 1 unit SPECIFICATIONS: "A. System Function -Throughput: Constant 240 tests per hour (w/o ISE), 400 tests per hour (w/ ISE)

  • Measuring Principles: Absorbance

Photometry, Turbidimetry, Ion Selective Electrode Technology

  • Methodology: Endpoint, Fixed-time,

Kinetic, Optional ISE, Single/Dual Reagent Chemistries, Monochromatic/Bichromatic, Linear/Nonlinear Multipoint Calibration

  • Original System pack reagent ready to use.

Close system and open system is optional.

  • Programming: Closed System with user

defined profiles and calculation chemistries. Optional Open System

  • Original system pack ready to use

Dedicated Reagent, Calibrator and Controls" "B. Reagent/Sample Handling

  • Reagent/Sample Tray: 50 to 100 positions

for reagents and 50 to 100 positions for samples in 24hour refrigerated compartment ( 2-12 deg C)

  • Reagent R1 Volume: 10-200uL step by

0.5Ul

  • Reagent R2 Volume: 10-200uL step by

0.5uL

  • Sample Volume: 2-35uL step by 0.1uL
  • Reagent/Sample Probe: Liquid level

detection and tracing, vertical and horizontal collision protection, inventory checking, reagent pre-warming, optional clog detection

  • Probe Cleaning: Automatic washing for

both interior and exterior side, Carryover <0.05%

  • Automatic Sample Dilution: Pre-dilution

and post-dilution, Dilution Ratio up to 1:200" " = Mixing Unit: Independent mixing bar = Built-in Bar Code Reader: Used for sample and reagent programming. Be applicable to various bar code systems of Cadabar, ITF (Interleaved Two of Five), code 128, code 39, UPC/EAN, Code93 Capable to communicate with LIS in bi-directional mode. = HBA1c Testing: Automatic, HBA1c Smart Sampling Function" "C. Optical System = Light Source: Halogen-Tungsten Lamp = Wavelength: 12 wavelengths, 340 nm, 380 nm, 412nm, 450nm, 505 nm, 546nm, 570nm, 605nm, 660nm, 700nm, 740nm, 800nm = Absorption Range: 0-3.5 Abs ( 10mm conversion) resolution 0.0001 Abs = Resolution: 0.0001 Abs = Stray Light: 4.9 Abs" "D. Reaction System = Reaction Rotor: Rotating tray containing 80 cuvettes = Cuvette: Reusable = Reaction Volume: 100-360Ul = Reaction Temperature 37 deg C +- 0.1 C = Temperature fluctuation +/-0.1 deg C = Mixing system Independent Mixing Bar = Cuvette Washing: 8-step wash station with pre-warmed detergent and water = One Key Calibrator Import Function = Reagent: There should be a dedicated reagent for the machine- reagent, controls and calibrator is same brand with the analyzer" "E. Control Calibration = Calibration modes: K Factor, Linear (two points and multi-points), Logit Log 4P, Logit- Log 5P, Spline, Exponential, Polynomial, Parabola, LogitLog 3P, Broken Line One Key Calibrator Import Function = Control Rules: Westgard multi rule, Levey Jennings, Cumulative sum check, Twin Plot" "F. Operation Unit = Operation System Windows 10 = Interface RS 232" "G. Working Conditions = Power Supply: 200 – 240v, 50/60Hz, ≤1300VA or 100-130V, 60hz ≤1300VA" " = Dimension: 860mm (Length) x 660mm (depth) x 550 mm (height) = Weight 115kg = Water Consumption ≤6.5L/H" 2 Fully Automated Five Parts Hematology Analyzer 1 unit SPECIFICATIONS: "Machine and Reagent Specifications: Principle: Impedance Method for RBC and PLT counting Cyanide free reagent for hemoglobin test Flow Cytometry (FCM) + Triangle laser scatter + Chemical Dye method for WBC 5 - part differential analysis and WBC counting Sample Volume: 15 μL whole blood mode or 20 μL pre-diluted mode Throughput: 60 samples per hour 25 Reportable Test Parameters and 24 Research Parameters 3 Histograms for WBC,RBC and PLT" "4 Scattergrams for WBC Differential Data Storage: at least 200,000 results including numeric and graphical information User Interface: 10.4 inch TFT Touch Screen Power Requirements: 100–240 V, 50–60 Hz Carryover: less than or equal to 1.00% for WBC, RBC, HGB, PLT Ambient Temperature: 10–30°C Humidity: 20%-85% Air Pressure:70kPa-106kPa supports 4 USB ports supports bi-directional LIS Weight: Maximum of 24kgs Dimensions: Maximum of 320mm x 400mm x 410 (WxDxH) Reagents: 3 main reagents plus 1 maintenance reagent Hematology Control: Contains at least the following per set: 1 Low, 1 Normal, 1 High Stable for atleast 14 days or more once opened Ready to use and should be delivered 3 sets per quarter Reagent Specifications: Diluent : 20L, Diff Lyse: 500ml, LH Lyse: 200ml Control Specifications: At least 3 months from the date of receipt of the end-user, Stable for atleast 14 days or more once opened, Ready to use Reagent Shelf Life: At least 6 months from the date of receipt of the end-user." 3 Biological Safety Cabinet 1 unit TECHNICAL PARAMETERS: " = Class II A =External size (W*D*H): 700X650X1230mm = Internal Size (W*D*H): 600X500X540mm = Tested Opening: Safety Height 200mm (8"") = Max Opening: 370mm (15"") =Inflow Velocity:0.53±0.025m/s = Downflow Velocity: 0.33±0.25m/s =HEPA Filter: Two, 99.999% efficiency at 0.3pm. Filter Life Indicator =Front Window: Motorized. Toughened glass. Anti UV =Noise: EN12469≤58dB /NSF49≤61dB = UV Lamp: 15W*1 UV timer, UV life indicator, emission of 253.7 nanometers for most efficient decontamination =LED Lamp: 8W*2 =Illumination: ≥1000 Lux =Consumption: 500W =Socket: Two, total load of two sockets: 500W =Display: LCD Display" " =Visual and Audio Alarm: Filter Replacement, window over height, abnormal air flow velocity =Material: Work zone: 304 stainless steel. Main Body: Cold-rolled steel with anti- bacteria powder coating =Work Surface Height: 750mm with optional base stand =Power Supply: AC220V±10%, 50/60Hz; 110V±10%, 60HZ =Standard Accessory: LED Lamp, UV Lamp*2, Remote Control, Waterproof socket*2 =Optional Accessory: Base stand, Universal caster with brake and leveling feet =Gross Weight Without Base Stand: Wooden box: 164 kg Carton: 121kg =Gross Weight with Base Stand: Wooden box: 196kg =Package Size without Base Stand: Wooden Box: 860*800*1450mm Carton: 820*760*1430mm =Package Size with Base Stand (W*D*H): Wooden Box: 860*960*1450mm" 4 Dental Chair 1 unit SPECIFICATIONS: "inclusions: =High Speed Air Turbine Hand Piece with Led Light =Ultrasonic Scaler with LED Light =Low Speed Air Turbine Hand Piece = Curing Light Built In = LED Lamp Sensored, High Med, Low = Chair with Memories = All Directional Head Rest = Rotary Assistant Position = X-film viewer (DC Low Voltage) = Strong and Weak Suction = Sanitary Seamless Cushion and Back Rest = Lower Chair Frame = Dentist Stool = Endoscope System (Intraoral Viewing System)" "Specifications: Power Supply Voltage: ACC220V, 50hz Air Source Pressure: 0.55MPA Water Source Pressure: 0.2mpa-0.4mpa Timotion DC motors Removable and rotatable cuspidor Chair position and compensation function Multi-functional foot control One piece tray, cup holder and tissue box LED Operation light with adjustable color temperature Rotatable handpiece holder Built out box with 2 meters and a main switch of water, air and power. Protective mat for instruments table Silicone mat for buttons 4 position assistant operation table Flexible light arm" 5 MICRO HEMATOCRIT CENTRIFUGE 1 unit SPECIFICATIONS: " =Motor: Universal Motor =Rotor: HT-24 =Speed (rpm): 12,000 (fixed) =Type: Disc =Capacity: 24 x capillary tube (1.5x75mm) =Timer (min): 0-15min, digital timer =Weight (kg): 5.1/5.6 =Overall Dimension: 300WX300DX240H" 6 CONTINUUM 1 unit "SPECIFICATIONS: Pre-bid Conference Date Time Venue 05/11/2026 10:00 AM BIDS AND AWARDS COMMITTEE OFFICE, 2ND FLOOR ,NEW CITY CENTER. POBLACION III,CARCAR CITY, CEBU Created by DOWIE JOY RODIS Date Created 27/10/2026 The PhilGEPS team is not responsible for any typographical errors or misinformation presented in the system. PhilGEPS only displays information provided for by its clients, and any queries regarding the postings should be directed to the contact person/s of the concerned party. ©&nbsp2004-2026 DBM Procurement Service. All rights reserved. Help | Contact Us | Sitemap

This presentation only restructures stored source text. It does not add quantities, specifications, or delivery terms.

Extracted from the stored notice

Key requirements

These checks organize what BidAssistant found. “Known from stored extraction” describes the source record, not your company’s eligibility. Unknowns remain verification items.

Submission & process

Pre-Bid Conference

Known from stored extraction

Required in stored extraction

A specific pre-bid conference is identified in the procurement notice.

This means the requirement is present in the stored extraction. It does not mean your company satisfies it.

Stored timeline

Important dates

Published · Manila

Oct 28, 2026, 12:00 AM

Deadline · Manila

Nov 18, 2026, 10:00 AM

18 days left
First saved / captured

Oct 28, 2026, 1:22 AM

Last database update

Oct 28, 2026, 1:22 AM

These are stored timestamps. A missing pre-bid or other procurement date is not shown.

Source and provenance

Official source

Open the stored PhilGEPS source link

Original reference
13312100
Original stored title
Purchase of Medical Equipment for medical services for the constituents of the City of Carcar
Original buying agency
CITY OF CARCAR, CEBU
Stored status
active
View original stored description
Item No. Item Description QTY. Unit Unit Price Total Price PURCHASE OF MEDICAL EQUIPMENTS FOR SUPER HEALTH CENTER 1 Clinical Chemistry Analyzer 1 unit SPECIFICATIONS: "A. System Function -Throughput: Constant 240 tests per hour (w/o ISE), 400 tests per hour (w/ ISE) - Measuring Principles: Absorbance Photometry, Turbidimetry, Ion Selective Electrode Technology - Methodology: Endpoint, Fixed-time, Kinetic, Optional ISE, Single/Dual Reagent Chemistries, Monochromatic/Bichromatic, Linear/Nonlinear Multipoint Calibration - Original System pack reagent ready to use. Close system and open system is optional. - Programming: Closed System with user defined profiles and calculation chemistries. Optional Open System - Original system pack ready to use Dedicated Reagent, Calibrator and Controls" "B. Reagent/Sample Handling - Reagent/Sample Tray: 50 to 100 positions for reagents and 50 to 100 positions for samples in 24hour refrigerated compartment ( 2-12 deg C) - Reagent R1 Volume: 10-200uL step by 0.5Ul - Reagent R2 Volume: 10-200uL step by 0.5uL - Sample Volume: 2-35uL step by 0.1uL - Reagent/Sample Probe: Liquid level detection and tracing, vertical and horizontal collision protection, inventory checking, reagent pre-warming, optional clog detection - Probe Cleaning: Automatic washing for both interior and exterior side, Carryover <0.05% - Automatic Sample Dilution: Pre-dilution and post-dilution, Dilution Ratio up to 1:200" " = Mixing Unit: Independent mixing bar = Built-in Bar Code Reader: Used for sample and reagent programming. Be applicable to various bar code systems of Cadabar, ITF (Interleaved Two of Five), code 128, code 39, UPC/EAN, Code93 Capable to communicate with LIS in bi-directional mode. = HBA1c Testing: Automatic, HBA1c Smart Sampling Function" "C. Optical System = Light Source: Halogen-Tungsten Lamp = Wavelength: 12 wavelengths, 340 nm, 380 nm, 412nm, 450nm, 505 nm, 546nm, 570nm, 605nm, 660nm, 700nm, 740nm, 800nm = Absorption Range: 0-3.5 Abs ( 10mm conversion) resolution 0.0001 Abs = Resolution: 0.0001 Abs = Stray Light: 4.9 Abs" "D. Reaction System = Reaction Rotor: Rotating tray containing 80 cuvettes = Cuvette: Reusable = Reaction Volume: 100-360Ul = Reaction Temperature 37 deg C +- 0.1 C = Temperature fluctuation +/-0.1 deg C = Mixing system Independent Mixing Bar = Cuvette Washing: 8-step wash station with pre-warmed detergent and water = One Key Calibrator Import Function = Reagent: There should be a dedicated reagent for the machine- reagent, controls and calibrator is same brand with the analyzer" "E. Control Calibration = Calibration modes: K Factor, Linear (two points and multi-points), Logit Log 4P, Logit- Log 5P, Spline, Exponential, Polynomial, Parabola, LogitLog 3P, Broken Line One Key Calibrator Import Function = Control Rules: Westgard multi rule, Levey Jennings, Cumulative sum check, Twin Plot" "F. Operation Unit = Operation System Windows 10 = Interface RS 232" "G. Working Conditions = Power Supply: 200 – 240v, 50/60Hz, ≤1300VA or 100-130V, 60hz ≤1300VA" " = Dimension: 860mm (Length) x 660mm (depth) x 550 mm (height) = Weight 115kg = Water Consumption ≤6.5L/H" 2 Fully Automated Five Parts Hematology Analyzer 1 unit SPECIFICATIONS: "Machine and Reagent Specifications: Principle: Impedance Method for RBC and PLT counting Cyanide free reagent for hemoglobin test Flow Cytometry (FCM) + Triangle laser scatter + Chemical Dye method for WBC 5 - part differential analysis and WBC counting Sample Volume: 15 μL whole blood mode or 20 μL pre-diluted mode Throughput: 60 samples per hour 25 Reportable Test Parameters and 24 Research Parameters 3 Histograms for WBC,RBC and PLT" "4 Scattergrams for WBC Differential Data Storage: at least 200,000 results including numeric and graphical information User Interface: 10.4 inch TFT Touch Screen Power Requirements: 100–240 V, 50–60 Hz Carryover: less than or equal to 1.00% for WBC, RBC, HGB, PLT Ambient Temperature: 10–30°C Humidity: 20%-85% Air Pressure:70kPa-106kPa supports 4 USB ports supports bi-directional LIS Weight: Maximum of 24kgs Dimensions: Maximum of 320mm x 400mm x 410 (WxDxH) Reagents: 3 main reagents plus 1 maintenance reagent Hematology Control: Contains at least the following per set: 1 Low, 1 Normal, 1 High Stable for atleast 14 days or more once opened Ready to use and should be delivered 3 sets per quarter Reagent Specifications: Diluent : 20L, Diff Lyse: 500ml, LH Lyse: 200ml Control Specifications: At least 3 months from the date of receipt of the end-user, Stable for atleast 14 days or more once opened, Ready to use Reagent Shelf Life: At least 6 months from the date of receipt of the end-user." 3 Biological Safety Cabinet 1 unit TECHNICAL PARAMETERS: " = Class II A =External size (W*D*H): 700X650X1230mm = Internal Size (W*D*H): 600X500X540mm = Tested Opening: Safety Height 200mm (8"") = Max Opening: 370mm (15"") =Inflow Velocity:0.53±0.025m/s = Downflow Velocity: 0.33±0.25m/s =HEPA Filter: Two, 99.999% efficiency at 0.3pm. Filter Life Indicator =Front Window: Motorized. Toughened glass. Anti UV =Noise: EN12469≤58dB /NSF49≤61dB = UV Lamp: 15W*1 UV timer, UV life indicator, emission of 253.7 nanometers for most efficient decontamination =LED Lamp: 8W*2 =Illumination: ≥1000 Lux =Consumption: 500W =Socket: Two, total load of two sockets: 500W =Display: LCD Display" " =Visual and Audio Alarm: Filter Replacement, window over height, abnormal air flow velocity =Material: Work zone: 304 stainless steel. Main Body: Cold-rolled steel with anti- bacteria powder coating =Work Surface Height: 750mm with optional base stand =Power Supply: AC220V±10%, 50/60Hz; 110V±10%, 60HZ =Standard Accessory: LED Lamp, UV Lamp*2, Remote Control, Waterproof socket*2 =Optional Accessory: Base stand, Universal caster with brake and leveling feet =Gross Weight Without Base Stand: Wooden box: 164 kg Carton: 121kg =Gross Weight with Base Stand: Wooden box: 196kg =Package Size without Base Stand: Wooden Box: 860*800*1450mm Carton: 820*760*1430mm =Package Size with Base Stand (W*D*H): Wooden Box: 860*960*1450mm" 4 Dental Chair 1 unit SPECIFICATIONS: "inclusions: =High Speed Air Turbine Hand Piece with Led Light =Ultrasonic Scaler with LED Light =Low Speed Air Turbine Hand Piece = Curing Light Built In = LED Lamp Sensored, High Med, Low = Chair with Memories = All Directional Head Rest = Rotary Assistant Position = X-film viewer (DC Low Voltage) = Strong and Weak Suction = Sanitary Seamless Cushion and Back Rest = Lower Chair Frame = Dentist Stool = Endoscope System (Intraoral Viewing System)" "Specifications: Power Supply Voltage: ACC220V, 50hz Air Source Pressure: 0.55MPA Water Source Pressure: 0.2mpa-0.4mpa Timotion DC motors Removable and rotatable cuspidor Chair position and compensation function Multi-functional foot control One piece tray, cup holder and tissue box LED Operation light with adjustable color temperature Rotatable handpiece holder Built out box with 2 meters and a main switch of water, air and power. Protective mat for instruments table Silicone mat for buttons 4 position assistant operation table Flexible light arm" 5 MICRO HEMATOCRIT CENTRIFUGE 1 unit SPECIFICATIONS: " =Motor: Universal Motor =Rotor: HT-24 =Speed (rpm): 12,000 (fixed) =Type: Disc =Capacity: 24 x capillary tube (1.5x75mm) =Timer (min): 0-15min, digital timer =Weight (kg): 5.1/5.6 =Overall Dimension: 300WX300DX240H" 6 CONTINUUM 1 unit "SPECIFICATIONS: Pre-bid Conference Date Time Venue 05/11/2026 10:00 AM BIDS AND AWARDS COMMITTEE OFFICE, 2ND FLOOR ,NEW CITY CENTER. POBLACION III,CARCAR CITY, CEBU Created by DOWIE JOY RODIS Date Created 27/10/2026 The PhilGEPS team is not responsible for any typographical errors or misinformation presented in the system. PhilGEPS only displays information provided for by its clients, and any queries regarding the postings should be directed to the contact person/s of the concerned party. ©&nbsp2004-2026 DBM Procurement Service. All rights reserved. Help | Contact Us | Sitemap

Freshness: First saved / captured Oct 28, 2026, 1:22 AM; last database update Oct 28, 2026, 1:22 AM.

New notices are collected periodically, but this service does not routinely refresh already-known notices. Stored dates and status may miss deadline extensions, cancellations, or amendments. Always check the latest official PhilGEPS notice. First-saved and last-update times describe our stored record, not a fresh check of the official notice.

BidAssistant PH is an independent discovery and screening aid, not PhilGEPS or a procuring agency.