Hospital / Medical EquipmentOpen · stored

PORTABLE DEFIBRILLATOR FOR AMBULANCE

Buying agencyLAS PIÑAS GENERAL HOSPITAL AND SATELLITE TRAUMA CENTER

Bid Brief

Is this bid worth a closer look?

Stored notice data. Confirm all decisions with the official documents.

Open · storedCompany screening · Not checked
Approved budget₱6,500,000.00
Time remaining5 days leftDeadline Nov 5, 2026, 9:00 AM
Company screeningCompany screening has not been run for this bid.
Main thing to check
No active requirements are storedNeeds verification
Why this matters

The complete eligibility conditions must be checked in the official bidding documents.

Next action
Review official notice

Use the supporting sections below to verify the evidence.

Reference 13281627

Decision support

Company Screening

Compare stored requirements with evidence from this browser. Unknown answers stay as Needs verification.

How screening states work
GO No known blocker foundREVIEW More information requiredNO-GO Known conflict

Checking the stored deadline…

Not checked yet

Add only the evidence relevant to this bid, or screen with unknown answers.

Open full Your Company profile

Not assessed yet

Source-backed scope

What they’re buying

Stored category: Hospital / Medical Equipment

Specification: MAIN FEATURES/FUNCTIONS: Rectilinear Biphasic Waveform Technology Provides ventilation feedback including rate and total volume in ml See-thru -reduces the duration of apuses during CPR by filtering out CPR artefact Integrated WIFI, Bluetooth® and USB cellular modem capabilities are standard as well O Acquires, stores, and transmits 12-leads RANGE (Parameters, Secondary dimensions and power) Defibrillator: (Manual / AED Mode) Rectilinear Biphasic Waveform Patient Impedance Range: 15 to 300 ohms Energy Selections: 1 to 10, 15, 20, 30, 50, 75, 100, 120, 150 and 200 joules Charge Time: Less than 7 seconds Paddle: External Apex/sternum paddle; adult plates slide off to expose pediatric surface Code Readiness Testing – verifies defibrillator hardware, therapy delivery cable, electrode condition and expiration without the need for a separate test fixture External Pacing Synchronized Mode Monitoring: ECG Monitoring- Patient Connection: 12 Lead ECG with 3-5 lead SPO2 sensor ETCO2 sensor NIBP RECORDER AND PRINTER: Type: High-resolution thermal array Annotation: Time, date, ECG lead, ECG gain, heart rate, defibrillation, and pacing parameters and treatment summary events Paper Width: 80 mm Memory Capacity: 24 hours of trends at 1-minute intervals, 500 time-stamped events, and 32 snapshots, including monitor, defibrillator, pacer, and treatment snapshots COMMUNICATION AND TRANSFER REQUIREMENT: WIFI Bluetooth USB BODY AND PHYSICAL FEATURES OF THE ITEMS: Enclosure Protection: Solid Foreign Object: IPX5 Operating: Temperature: 0 to 50oC Humidity: 15 to 95% RH (non-condensing) Vibration: Military standard Shock Proof Drop: EN 1789 Altitude: -170 m to 4572 m (-557 feet to 15,000 feet) Size: 9 X W X D) less than 10in all sides Weight: less than 6kg Size: Less than 10in diagonal Input: 3 lead, 5-lead, of 12-lead patient cable, paddles, or multifunction electrodes Type: Color LC, 640 x 480 pixels At least 3 hours charging time Passed the EN 1789 standard for altitude testing ACCESSORIES: AC Power Adapter: 100 – 240 VAC 50, 60 Hz, 2A 100 – 115 VAC 400Hz, 2A Type: Rechargeable lithium-ion, 11.1 Vdc, 6.6 Ah, 73 Wh; Battery alone can discharge 300 Shocks at 200J and 10 discharge at 200J if with low battery indication Pads / Electrodes for Defibrillation, Pacing, Cardioversion and CPR CPR Connector Recording Paper NIBP Cuff • ETCO2 Sensor Pulse Oximeter Sensor 12 L ECG Simulator Accessory Bag Fixing Bracket OTHERS: At least three (3) years warranty, with additional service unit and dedicated maintenance provider Availability of parts and services for at least five (5) years At least two (2) copies of training manual for end-user and Biomed. Provision of High Performing Resuscitation and team dynamic workshop

This presentation only restructures stored source text. It does not add quantities, specifications, or delivery terms.

Extracted from the stored notice

Key requirements

These checks organize what BidAssistant found. “Known from stored extraction” describes the source record, not your company’s eligibility. Unknowns remain verification items.

No active requirements are stored.

Review the official notice and bidding documents for the complete requirements.

Stored timeline

Important dates

Published · Manila

Oct 10, 2026, 12:00 AM

Deadline · Manila

Nov 5, 2026, 9:00 AM

5 days left
First saved / captured

Oct 10, 2026, 2:41 AM

Last database update

Oct 10, 2026, 2:41 AM

These are stored timestamps. A missing pre-bid or other procurement date is not shown.

Source and provenance

Official source

Open the stored PhilGEPS source link

Original reference
13281627
Original stored title
PORTABLE DEFIBRILLATOR FOR AMBULANCE
Original buying agency
LAS PIÑAS GENERAL HOSPITAL AND SATELLITE TRAUMA CENTER
Stored status
active
View original stored description
PORTABLE DEFIBRILLATOR FOR AMBULANCE Specification: MAIN FEATURES/FUNCTIONS: Rectilinear Biphasic Waveform Technology Provides ventilation feedback including rate and total volume in ml See-thru -reduces the duration of apuses during CPR by filtering out CPR artefact Integrated WIFI, Bluetooth® and USB cellular modem capabilities are standard as well O Acquires, stores, and transmits 12-leads RANGE (Parameters, Secondary dimensions and power) Defibrillator: (Manual / AED Mode) Rectilinear Biphasic Waveform Patient Impedance Range: 15 to 300 ohms Energy Selections: 1 to 10, 15, 20, 30, 50, 75, 100, 120, 150 and 200 joules Charge Time: Less than 7 seconds Paddle: External Apex/sternum paddle; adult plates slide off to expose pediatric surface Code Readiness Testing – verifies defibrillator hardware, therapy delivery cable, electrode condition and expiration without the need for a separate test fixture External Pacing Synchronized Mode Monitoring: ECG Monitoring- Patient Connection: 12 Lead ECG with 3-5 lead SPO2 sensor ETCO2 sensor NIBP RECORDER AND PRINTER: Type: High-resolution thermal array Annotation: Time, date, ECG lead, ECG gain, heart rate, defibrillation, and pacing parameters and treatment summary events Paper Width: 80 mm Memory Capacity: 24 hours of trends at 1-minute intervals, 500 time-stamped events, and 32 snapshots, including monitor, defibrillator, pacer, and treatment snapshots COMMUNICATION AND TRANSFER REQUIREMENT: WIFI Bluetooth USB BODY AND PHYSICAL FEATURES OF THE ITEMS: Enclosure Protection: Solid Foreign Object: IPX5 Operating: Temperature: 0 to 50oC Humidity: 15 to 95% RH (non-condensing) Vibration: Military standard Shock Proof Drop: EN 1789 Altitude: -170 m to 4572 m (-557 feet to 15,000 feet) Size: 9 X W X D) less than 10in all sides Weight: less than 6kg Size: Less than 10in diagonal Input: 3 lead, 5-lead, of 12-lead patient cable, paddles, or multifunction electrodes Type: Color LC, 640 x 480 pixels At least 3 hours charging time Passed the EN 1789 standard for altitude testing ACCESSORIES: AC Power Adapter: 100 – 240 VAC 50, 60 Hz, 2A 100 – 115 VAC 400Hz, 2A Type: Rechargeable lithium-ion, 11.1 Vdc, 6.6 Ah, 73 Wh; Battery alone can discharge 300 Shocks at 200J and 10 discharge at 200J if with low battery indication Pads / Electrodes for Defibrillation, Pacing, Cardioversion and CPR CPR Connector Recording Paper NIBP Cuff • ETCO2 Sensor Pulse Oximeter Sensor 12 L ECG Simulator Accessory Bag Fixing Bracket OTHERS: At least three (3) years warranty, with additional service unit and dedicated maintenance provider Availability of parts and services for at least five (5) years At least two (2) copies of training manual for end-user and Biomed. Provision of High Performing Resuscitation and team dynamic workshop

Freshness: First saved / captured Oct 10, 2026, 2:41 AM; last database update Oct 10, 2026, 2:41 AM.

New notices are collected periodically, but this service does not routinely refresh already-known notices. Stored dates and status may miss deadline extensions, cancellations, or amendments. Always check the latest official PhilGEPS notice. First-saved and last-update times describe our stored record, not a fresh check of the official notice.

BidAssistant PH is an independent discovery and screening aid, not PhilGEPS or a procuring agency.