Hospital / Medical EquipmentOpen · stored

ELECTROCAUTERY MACHINE (REBID)

Buying agencyLAS PIÑAS GENERAL HOSPITAL AND SATELLITE TRAUMA CENTER

Bid Brief

Is this bid worth a closer look?

Stored notice data. Confirm all decisions with the official documents.

Open · storedCompany screening · Not checked
Approved budget₱3,400,000.00
Time remaining5 days leftDeadline Nov 5, 2026, 9:00 AM
Company screeningCompany screening has not been run for this bid.
Main thing to check
No active requirements are storedNeeds verification
Why this matters

The complete eligibility conditions must be checked in the official bidding documents.

Next action
Review official notice

Use the supporting sections below to verify the evidence.

Reference 13281606

Decision support

Company Screening

Compare stored requirements with evidence from this browser. Unknown answers stay as Needs verification.

How screening states work
GO No known blocker foundREVIEW More information requiredNO-GO Known conflict

Checking the stored deadline…

Not checked yet

Add only the evidence relevant to this bid, or screen with unknown answers.

Open full Your Company profile

Not assessed yet

Source-backed scope

What they’re buying

Stored category: Hospital / Medical Equipment

ELECTROCAUTERY MACHINE Specification:

  • Heavy duty with monopolar and bipolar modes
  • With at least 5 inches LCD touch screen control and one key recover button or its equivalent
  • Configuration can be preset and saved according to the users’ habit
  • Support the connection of adult per neonatal type neutral electrodes and split/non-split neutral electrode
  • Power Supply: 110V/240VB AC, 50-60Hz (standard electrical configuration)
  • Control modes: Manual and foot operated and wireless foot operated options
  • High frequency: at least 300 kHz
  • Power output adjustable power levels: 0 to 120W for monopolar, at least 70W for bipolar mode, at least 400W for monopolar-cut, at least 150W for monopolar-coag, at least 100W for bipolar-cut, 100 watts for bipolar-coag, pure-cut 0-300W, blend-cut 0-200W, and coagulation 0-120W
  • With cutting mode, blend mode, spray mode and coagulation mode
  • Dimension: Length=at least 38cm; Width=at least 31cm; Height=at least 12cm; Weight=at least 5kg
  • With heavy duty trolley equipped with a heavy duty casters and secure wheel locks for safe, stable and easy mobility

Standard requirements:

  • Bidder’s certificate that parts and consumables shall be available at the authorized Philippine service center/s for five (5) years after the warranty period
  • Three (3) years warranty on parts and services and provision of appropriate calibration tools for preventive maintenance
  • Must provide operating manual
  • The proponent must have a local repair facility and availability of a service technician and/or biomedical engineer within 48 hours (except weekends and holidays) upon receipt of notice in case of equipment breakdown during the warranty period
  • With a loaner unit to ensure uninterrupted operations whenever the equipment is under repair or maintenance
  • Bidder must have at least 5 service Engineer/Technical with a National Certificate II in Biomedical Equipment servicing
  • Compatibility with existing Laparoscopic Towers
  • The electrosurgical unit must be fully compatible with the existing laparoscopic tower systems currently installed at the Las Piñas General Hospital and Satellite Trauma Center Operating Room Complex
  • The supplier shall provide documentary evidence or certification of compatibility with the following existing laparoscopic tower brand (Karl Storz)
  • Compatibility with existing consumables
  • The electrosurgical unit must be compatible with the hospital’s existing electrosurgical consumables to avoid additional procurement costs and ensure continuity of service
  • Compatibility shall include, but not limited to:
  • Existing disposable and reusable electrosurgical pencils (electrocautery pens)
  • Existing patient return electrodes (electrocautery pads), both split and non-split types currently in use
  • The supplier shall provide written certification and demonstrate compatibility during product evaluation and acceptance testing
  • No propriety lock-in
  • The offered unit shall not require exclusive proprietary consumables if equivalent existing hospital consumables are available and compatible
  • Use of existing hospital stocks of electrocautery pads and electrocautery pens shall not compromise the functionality, safety features, or warranty of the equipment

This presentation only restructures stored source text. It does not add quantities, specifications, or delivery terms.

Extracted from the stored notice

Key requirements

These checks organize what BidAssistant found. “Known from stored extraction” describes the source record, not your company’s eligibility. Unknowns remain verification items.

No active requirements are stored.

Review the official notice and bidding documents for the complete requirements.

Stored timeline

Important dates

Published · Manila

Oct 10, 2026, 12:00 AM

Deadline · Manila

Nov 5, 2026, 9:00 AM

5 days left
First saved / captured

Oct 10, 2026, 2:41 AM

Last database update

Oct 10, 2026, 2:41 AM

These are stored timestamps. A missing pre-bid or other procurement date is not shown.

Source and provenance

Official source

Open the stored PhilGEPS source link

Original reference
13281606
Original stored title
ELECTROCAUTERY MACHINE (REBID)
Original buying agency
LAS PIÑAS GENERAL HOSPITAL AND SATELLITE TRAUMA CENTER
Stored status
active
View original stored description
ELECTROCAUTERY MACHINE Specification: - Heavy duty with monopolar and bipolar modes - With at least 5 inches LCD touch screen control and one key recover button or its equivalent - Configuration can be preset and saved according to the users’ habit - Support the connection of adult per neonatal type neutral electrodes and split/non-split neutral electrode - Power Supply: 110V/240VB AC, 50-60Hz (standard electrical configuration) - Control modes: Manual and foot operated and wireless foot operated options - High frequency: at least 300 kHz - Power output adjustable power levels: 0 to 120W for monopolar, at least 70W for bipolar mode, at least 400W for monopolar-cut, at least 150W for monopolar-coag, at least 100W for bipolar-cut, 100 watts for bipolar-coag, pure-cut 0-300W, blend-cut 0-200W, and coagulation 0-120W - With cutting mode, blend mode, spray mode and coagulation mode - Dimension: Length=at least 38cm; Width=at least 31cm; Height=at least 12cm; Weight=at least 5kg - With heavy duty trolley equipped with a heavy duty casters and secure wheel locks for safe, stable and easy mobility Standard requirements: - Bidder’s certificate that parts and consumables shall be available at the authorized Philippine service center/s for five (5) years after the warranty period - Three (3) years warranty on parts and services and provision of appropriate calibration tools for preventive maintenance - Must provide operating manual - The proponent must have a local repair facility and availability of a service technician and/or biomedical engineer within 48 hours (except weekends and holidays) upon receipt of notice in case of equipment breakdown during the warranty period - With a loaner unit to ensure uninterrupted operations whenever the equipment is under repair or maintenance - Bidder must have at least 5 service Engineer/Technical with a National Certificate II in Biomedical Equipment servicing - Compatibility with existing Laparoscopic Towers - The electrosurgical unit must be fully compatible with the existing laparoscopic tower systems currently installed at the Las Piñas General Hospital and Satellite Trauma Center Operating Room Complex - The supplier shall provide documentary evidence or certification of compatibility with the following existing laparoscopic tower brand (Karl Storz) - Compatibility with existing consumables - The electrosurgical unit must be compatible with the hospital’s existing electrosurgical consumables to avoid additional procurement costs and ensure continuity of service - Compatibility shall include, but not limited to: - Existing disposable and reusable electrosurgical pencils (electrocautery pens) - Existing patient return electrodes (electrocautery pads), both split and non-split types currently in use - The supplier shall provide written certification and demonstrate compatibility during product evaluation and acceptance testing - No propriety lock-in - The offered unit shall not require exclusive proprietary consumables if equivalent existing hospital consumables are available and compatible - Use of existing hospital stocks of electrocautery pads and electrocautery pens shall not compromise the functionality, safety features, or warranty of the equipment

Freshness: First saved / captured Oct 10, 2026, 2:41 AM; last database update Oct 10, 2026, 2:41 AM.

New notices are collected periodically, but this service does not routinely refresh already-known notices. Stored dates and status may miss deadline extensions, cancellations, or amendments. Always check the latest official PhilGEPS notice. First-saved and last-update times describe our stored record, not a fresh check of the official notice.