Stored category: Hospital / Medical Equipment
1 Description of Function It is used to the surface imaging of superficial structures beyond the skin as, nerves, arteries, veins, adjacent muscles, ligament, and soft tissues. It safety aids in inserting invasive monitors. 2 Operational Requirements 2.1 System complete with all accessories as specified in the Technical Specifications below. 2.2 3 year warranty 2.3 Maintenance service every 6 months during warranty period and calibration 2.4 Availability of back up unit to replace defective unit while on-going repair
3.1 Ultrasound guidance for vascular access procedures should be performed during broadband high-resolution linear array transducers 3.1.1 Frequencies between 7.5 and 18 MHz is preferred 3.1.2 Single probe that will cover this frequency adjustable for high frequency viewing superficial vessel 3.1.3 This probe can also be adjustable to lower frequency for deeper vessel viewing (look for lowest during pre-bid) 3.2 Small-footprint probes (including the “hockey stick” - type probe) may be helpful in pediatric patients or in areas where space is limited, such as near the clavicle. 3.3 Color of spectral Doppler imaging may be helpful for identifying flow in vascular structures and in aiding the differentiation of arteries and veins. 3.4 Above 10 inch. high resolution, flat pane; medical grade monitor 2 megapixel with wide viewing angle and good color resolution. 3.4.1 Resolution: 1024 x 728 pixels are better. 3.4.2 Physical Dimensions: 11.6-inch high resolution screen, weight: 2.4 kg with the kickstand, 319.6 x 223.2 x 31.8mm 3.4.3 Unit should be as per manufacturer's dimension with multi-transducer module allowing simultaneous connectivity of 3 transducer switching from the software user interface. 3.4.4 Wheel casters with breaks
4.1 In addition to ultrasound equipment, certain additional equipment listed below 4.1.1 Thermal paper and ultrasound gel, black and white printer 4.1.2 100 pieces sterile probe covers 4.1.3 2 tubes of ultrasound gel
4.1 The unit shall be capable of being stored continuously in ambient temperature of 0-50 deg C and relative humidity of 15-90% 5.2 The unit shall be capable of operating in ambient temperature of 20-30 deg C and relative humidity of less than 70%
6.1 Power adapter AC input: 100-240 VAC, 50/60Hz fitted with PHC electrical outlet, 1.7 A (max). Adapter DC output: 19 V, 3.4 A
7.1 Manufacturers/Supplier should have a valid ISO 13485 certificate of Quality Management System for Medical devices. 7.2 The equipment shall be certified as compliant with IEC 60601-1, EN 60601-1, ANSI/AAMI ES60601-1, Or other equivalent internationally recognized electrical safety standards applicable to medical electrical equipment. 7.3 The equipment must conform to recognized and verifiable international or regional standards, as evidenced by certification such as CE, UL or BIS or other equivalent standards issued by accredited certification or regulatory bodies. 7.4 The product shall be FDA-approved/registered. If FDA registration has not yet been issued, the bidder may submit proof of a pending FDA application, such as CMDN, CMDR, or other equivalent FDA-Issued or FDA-acknowledgement document. 7.5 Comprehensive Technical Training for PHC BIOMED and User's training to staff for familiarity with the system 7.6 The supplier must submit a certificate that it shall conduct PMS on a quarterly basis for a minimum of one (1) year. 7.7 Shall meet IEC-60601-1-2: 2014 (Or Equivalent BIS) General Requirements of Safety for Electromagnetic Compatibility or should comply with 89/336/EEC; EMC-directive
8.1 Integrated Wi-fi, Bluetooth, and Ethernet for data transfer. 8.2 Compatibility with Android/iOS devices for remote access and monitoring 8.3 USB ports and cloud storage export capability
9.1 Similar unit
10.1 60 days
11.1 Autorized
12.1 User/Technical/Maintenance manuals to be supplied in English. 12.2 Certificate of calibration and inspection. 12.3 List of important spare parts and accessories with their part number and costing. 12.4 List of Equipments available for providing calibration and routine maintenance support as per manufacturer documentation in service/technical manual Pre-bid Conference Date Time Venue 22/10/2026 10:00 AM Philippine Heart Center East Avenue, Quezon City 5th Floor, Old Chapel, Hospital Bldg., PHC Other Information Description ABC
Created by Rachelle Henson Cortez Date Created 12/10/2026 The PhilGEPS team is not responsible for any typographical errors or misinformation presented in the system. PhilGEPS only displays information provided for by its clients, and any queries regarding the postings should be directed to the contact person/s of the concerned party. © 2004-2026 DBM Procurement Service. All rights reserved. Help | Contact Us | Sitemap
This presentation only restructures stored source text. It does not add quantities, specifications, or delivery terms.
These checks organize what BidAssistant found. “Known from stored extraction” describes the source record, not your company’s eligibility. Unknowns remain verification items.
Bidder must satisfy the stated Single Largest Completed Contract requirement.
This means the requirement is present in the stored extraction. It does not mean your company satisfies it.
A specific pre-bid conference is identified in the procurement notice.
This means the requirement is present in the stored extraction. It does not mean your company satisfies it.
Oct 13, 2026, 12:00 AM
Nov 26, 2026, 10:00 AM
26 days leftOct 13, 2026, 3:57 AM
Oct 13, 2026, 3:57 AM
These are stored timestamps. A missing pre-bid or other procurement date is not shown.
Open the stored PhilGEPS source link
Freshness: First saved / captured Oct 13, 2026, 3:57 AM; last database update Oct 13, 2026, 3:57 AM.
New notices are collected periodically, but this service does not routinely refresh already-known notices. Stored dates and status may miss deadline extensions, cancellations, or amendments. Always check the latest official PhilGEPS notice. First-saved and last-update times describe our stored record, not a fresh check of the official notice.
BidAssistant PH is an independent discovery and screening aid, not PhilGEPS or a procuring agency.