Laboratory Supplies and EquipmentOpen · stored

Supply of One (1) Refrigerated Vacuum Concentrator with Accessories for Project 1: GARLICHEM (GARlic Lead Compound Identification and CHEMical Mapping)

Buying agencyUNIVERSITY OF THE PHILIPPINES - MANILA

Bid Brief

Is this bid worth a closer look?

Stored notice data. Confirm all decisions with the official documents.

Open · storedCompany screening · Not checked
Approved budget₱2,550,000.00
Time remaining4 days leftDeadline Nov 4, 2026, 11:30 AM
Company screeningCompany screening has not been run for this bid.
Main thing to check
4 days leftNeeds verification
Why this matters

The stored deadline is approaching. Confirm the official deadline before investing more time.

Next action
Check my company now

Use the supporting sections below to verify the evidence.

Reference 13283427

Decision support

Company Screening

Compare stored requirements with evidence from this browser. Unknown answers stay as Needs verification.

How screening states work
GO No known blocker foundREVIEW More information requiredNO-GO Known conflict

Checking the stored deadline…

Not checked yet

Add only the evidence relevant to this bid, or screen with unknown answers.

Open full Your Company profile

Not assessed yet

Source-backed scope

What they’re buying

Stored category: Laboratory Supplies and Equipment

Supply of One (1) Refrigerated vacuum concentrator with accessories ● Should be able to concentrate heat-sensitive samples (e.g. RNA, proteins) using centrifugal force, vacuum, and controlled temperature ● Refrigerated chamber should be capable of maintaining ≤ -4°C ● Upper chamber temperature of at least 100°C ● Temperature and run time settings should be programmable ● Rotor speed should be at least 1,700 rpm ● User adjustable rotor speed, including in-run adjustments ● Built-in delay before vacuum application ● Programmable vacuum-pressure control ● Automatic vacuum release post-run ● User-programmable stored methods, aside from pre-programmed methods ● Modification of multiple parameters during an active run ● Should be able to cater to 1.5 to 2-mL microcentrifuge tubes, 15-, and 50-mL conical tubes (with applicable rotors) ● Acid-resistant concentrator construction ● Vapor-condensation/trapping system included ● Vacuum pump/system included ● Should be able to detect any rotor imbalance ● Lid/interlock safety should be included ● Phenol-free chamber/lid gasket ● Appropriate 220–240 V, 60-Hz operation for Philippine laboratory supply ● Voltage conditioning (e.g. 3-kVA AVR) should be included ● One-day on-site training for proper operation and preventive maintenance should be provided ● Other Specifications for Refrigerated Centrifuge:

  • Weight: Not more than 45 kg
  • Dimensions: Not more than W x D x H - 32 x 70 x 43 cm
  • Chemical Resistance: Acid-resistant
  • Lid Type: Glass, solvent-resistant
  • HCFC/CFC-free natural glass refrigeration system to cool chamber
  • Real time chamber temperature monitoring and control
  • Capable of small scale benchtop lyophilization (in combination with vacuum pump and cold trap)
  • Conforms to standard safety conformance regulations

● Other Specifications for vapor-condensation/trapping system

  • Weight: Not more than 68 kgs
  • Dimensions: Not more than W x D x H - 62 x 61 x 45 cm
  • HCFC-Free refrigeration system
  • 4-Liter, Stainless Steel Collector
  • Should have a stainless steel drain port (with corrosion-resistant nylon valve)
  • Collector Temperature: Should be able to reach -105°C
  • Lid Type: Stainless Steel
  • Conforms to UKCA, CE, or equivalent standard safety conformance regulations

● Other Specifications for the Vacuum Pump

  • Weight: Not more than 15 kg
  • Dimensions: Not more than W x D x H 9.6” x 8.3” x 7.8”
  • Electrical: 230 V, 50/60Hz, 1.8A or equivalent
  • Pump Type: Diaphragm Vacuum Pump

● Other Accessories:

  • PTFE-coated rotor for 1.5 to 2-mL microcentrifuge tubes
  • PTFE-coated rotor for 15- and 50-mL conical tubes
  • Clear Canister or equivalent
  • Solvent trap insert or equivalent
  • Glass insert for a 4-L Cold Trap or equivalent
  • 3-kVA AVR

Terms and Conditions Delivery terms:  Delivery shall be made 90 to 120 days from receipt of Purchase Order  120 days shall be subject to approval of the end-user Payment terms:  Payment shall be made in accordance with Government Terms. Packing and Shipping:  Items should be properly packed and delivered in accordance with the recommended storage/shipping conditions. Warranty/Replacement of items:  The instrument is covered by a warranty for a period of one (1) year from the date of operational installation and training. Any defects in materials or workmanship that arise under normal use will be repaired free of charge, including both the cost of spare parts and applicable service fees. The warranty does not cover damage resulting from misuse, accidents, unauthorized modifications, or improper maintenance. Delivery Place:  All items shall be delivered at the Department of Biochemistry and Molecular Biology, G/F Salcedo Hall, College of Medicine, University of the Philippines Manila Additional Requirements:  The brand to be offered must have been on the market for more than 10 years.  Items to be offered should preferably be cited in publications/references.  Items with certification/compliance requirements should include certificates of analysis/compliance/clean claims.  The company must have been in the Philippine industry for more than 10 years and have a good record. Optional: provide satisfactory after-sales records. Pre-bid Conference Date Time Venue 21/10/2026 1:30 PM The University of the Philippines-Manila, will hold a Pre-Bid Conference on 21 October 2026, the meeting will start at 01:30 p.m. and will follow the agenda for the day at the Procurement Management Office Conference Room at 2nd Floor Joaquin Gonzales Bui Created by MELODY JANE LISING ROJO Date Created 12/10/2026 The PhilGEPS team is not responsible for any typographical errors or misinformation presented in the system. PhilGEPS only displays information provided for by its clients, and any queries regarding the postings should be directed to the contact person/s of the concerned party. ©&nbsp2004-2026 DBM Procurement Service. All rights reserved. Help | Contact Us | Sitemap

This presentation only restructures stored source text. It does not add quantities, specifications, or delivery terms.

Extracted from the stored notice

Key requirements

These checks organize what BidAssistant found. “Known from stored extraction” describes the source record, not your company’s eligibility. Unknowns remain verification items.

Submission & process

Pre-Bid Conference

Known from stored extraction

Required in stored extraction

A specific pre-bid conference is identified in the procurement notice.

This means the requirement is present in the stored extraction. It does not mean your company satisfies it.

Stored timeline

Important dates

Published · Manila

Oct 13, 2026, 12:00 AM

Deadline · Manila

Nov 4, 2026, 11:30 AM

4 days left
First saved / captured

Oct 13, 2026, 4:00 AM

Last database update

Oct 13, 2026, 4:00 AM

These are stored timestamps. A missing pre-bid or other procurement date is not shown.

Source and provenance

Official source

Open the stored PhilGEPS source link

Original reference
13283427
Original stored title
Supply of One (1) Refrigerated Vacuum Concentrator with Accessories for Project 1: GARLICHEM (GARlic Lead Compound Identification and CHEMical Mapping)
Original buying agency
UNIVERSITY OF THE PHILIPPINES - MANILA
Stored status
active
View original stored description
Supply of One (1) Refrigerated vacuum concentrator with accessories ● Should be able to concentrate heat-sensitive samples (e.g. RNA, proteins) using centrifugal force, vacuum, and controlled temperature ● Refrigerated chamber should be capable of maintaining ≤ -4°C ● Upper chamber temperature of at least 100°C ● Temperature and run time settings should be programmable ● Rotor speed should be at least 1,700 rpm ● User adjustable rotor speed, including in-run adjustments ● Built-in delay before vacuum application ● Programmable vacuum-pressure control ● Automatic vacuum release post-run ● User-programmable stored methods, aside from pre-programmed methods ● Modification of multiple parameters during an active run ● Should be able to cater to 1.5 to 2-mL microcentrifuge tubes, 15-, and 50-mL conical tubes (with applicable rotors) ● Acid-resistant concentrator construction ● Vapor-condensation/trapping system included ● Vacuum pump/system included ● Should be able to detect any rotor imbalance ● Lid/interlock safety should be included ● Phenol-free chamber/lid gasket ● Appropriate 220–240 V, 60-Hz operation for Philippine laboratory supply ● Voltage conditioning (e.g. 3-kVA AVR) should be included ● One-day on-site training for proper operation and preventive maintenance should be provided ● Other Specifications for Refrigerated Centrifuge: - Weight: Not more than 45 kg - Dimensions: Not more than W x D x H - 32 x 70 x 43 cm - Chemical Resistance: Acid-resistant - Lid Type: Glass, solvent-resistant - HCFC/CFC-free natural glass refrigeration system to cool chamber - Real time chamber temperature monitoring and control - Capable of small scale benchtop lyophilization (in combination with vacuum pump and cold trap) - Conforms to standard safety conformance regulations ● Other Specifications for vapor-condensation/trapping system - Weight: Not more than 68 kgs - Dimensions: Not more than W x D x H - 62 x 61 x 45 cm - HCFC-Free refrigeration system - 4-Liter, Stainless Steel Collector - Should have a stainless steel drain port (with corrosion-resistant nylon valve) - Collector Temperature: Should be able to reach -105°C - Lid Type: Stainless Steel - Conforms to UKCA, CE, or equivalent standard safety conformance regulations ● Other Specifications for the Vacuum Pump - Weight: Not more than 15 kg - Dimensions: Not more than W x D x H 9.6” x 8.3” x 7.8” - Electrical: 230 V, 50/60Hz, 1.8A or equivalent - Pump Type: Diaphragm Vacuum Pump ● Other Accessories: - PTFE-coated rotor for 1.5 to 2-mL microcentrifuge tubes - PTFE-coated rotor for 15- and 50-mL conical tubes - Clear Canister or equivalent - Solvent trap insert or equivalent - Glass insert for a 4-L Cold Trap or equivalent - 3-kVA AVR Terms and Conditions Delivery terms:  Delivery shall be made 90 to 120 days from receipt of Purchase Order  120 days shall be subject to approval of the end-user Payment terms:  Payment shall be made in accordance with Government Terms. Packing and Shipping:  Items should be properly packed and delivered in accordance with the recommended storage/shipping conditions. Warranty/Replacement of items:  The instrument is covered by a warranty for a period of one (1) year from the date of operational installation and training. Any defects in materials or workmanship that arise under normal use will be repaired free of charge, including both the cost of spare parts and applicable service fees. The warranty does not cover damage resulting from misuse, accidents, unauthorized modifications, or improper maintenance. Delivery Place:  All items shall be delivered at the Department of Biochemistry and Molecular Biology, G/F Salcedo Hall, College of Medicine, University of the Philippines Manila Additional Requirements:  The brand to be offered must have been on the market for more than 10 years.  Items to be offered should preferably be cited in publications/references.  Items with certification/compliance requirements should include certificates of analysis/compliance/clean claims.  The company must have been in the Philippine industry for more than 10 years and have a good record. Optional: provide satisfactory after-sales records. Pre-bid Conference Date Time Venue 21/10/2026 1:30 PM The University of the Philippines-Manila, will hold a Pre-Bid Conference on 21 October 2026, the meeting will start at 01:30 p.m. and will follow the agenda for the day at the Procurement Management Office Conference Room at 2nd Floor Joaquin Gonzales Bui Created by MELODY JANE LISING ROJO Date Created 12/10/2026 The PhilGEPS team is not responsible for any typographical errors or misinformation presented in the system. PhilGEPS only displays information provided for by its clients, and any queries regarding the postings should be directed to the contact person/s of the concerned party. ©&nbsp2004-2026 DBM Procurement Service. All rights reserved. Help | Contact Us | Sitemap

Freshness: First saved / captured Oct 13, 2026, 4:00 AM; last database update Oct 13, 2026, 4:00 AM.

New notices are collected periodically, but this service does not routinely refresh already-known notices. Stored dates and status may miss deadline extensions, cancellations, or amendments. Always check the latest official PhilGEPS notice. First-saved and last-update times describe our stored record, not a fresh check of the official notice.

BidAssistant PH is an independent discovery and screening aid, not PhilGEPS or a procuring agency.