Laboratory Supplies and EquipmentOpen · stored

Supply of Screening Device (General for ABR: Artifact Rejection: Weighted Averaging, Notch Filter (50/60 Hz, Self-Tuning))

Buying agencyUNIVERSITY OF THE PHILIPPINES - MANILA

Bid Brief

Is this bid worth a closer look?

Stored notice data. Confirm all decisions with the official documents.

Open · storedCompany screening · Not checked
Approved budget₱3,333,333.00
Time remaining4 days leftDeadline Nov 4, 2026, 11:30 AM
Company screeningCompany screening has not been run for this bid.
Main thing to check
4 days leftNeeds verification
Why this matters

The stored deadline is approaching. Confirm the official deadline before investing more time.

Next action
Check my company now

Use the supporting sections below to verify the evidence.

Reference 13283335

Decision support

Company Screening

Compare stored requirements with evidence from this browser. Unknown answers stay as Needs verification.

How screening states work
GO No known blocker foundREVIEW More information requiredNO-GO Known conflict

Checking the stored deadline…

Not checked yet

Add only the evidence relevant to this bid, or screen with unknown answers.

Open full Your Company profile

Not assessed yet

Source-backed scope

What they’re buying

Stored category: Laboratory Supplies and Equipment

AABR/ABR Screening Device with wireless 3G module technology General AABR/ABR Specifications Artifact Rejection Weighted averaging, notch filter (50/60 Hz, self-tuning) Residual Noise Calculation Collects noise energy per frame; calculates residual noise level (RMS in nV) Response Detection Auto peak-marker, template matching Normative Latencies For different age groups and transducer types Electrode Impedance Check Continuous monitoring; auto-start after impedance OK (R ≤ 4 kΩ, ΔR ≤ 2 kΩ) Sample Rate 48 kHz (stimulus); 16 kHz (response) Stimulus Parameters Stimulus Types Click (0.7–6 kHz), Chirp (broadband, 1–8 kHz), Tone Burst (500 Hz–4 kHz) Stimulus Polarity Condensation, rarefaction, alternating Stimulus Rate 10.1, 20.3, 30.7, 40.3, 69.9, 81.2, 90.4 Hz (default); user-defined 10–100 Hz Stimulus Levels 0 to max. 95 dB nHL (or transducer limits); Quick ABR screening: 35–55 dB eHL Masking Noise Offset -50 to +50 dB (white noise) Averages 1,000 to 20,000; step size: 1,000 Noise Stop Criterion 0, 10, 15, 20, 30, 40, 50, 60, 80 nV Automated Wave 5 Detection Minimum wave 5 criterion: 0, 20, 30, 40, 50, 70, 100, 150, 200 nVpp (optional) Plot Range (fixed) 0 to inter-stimulus interval + 1.5 ms (min. 10.5 ms; max. 15 ms) Physical / Interface Specifications Display 3.5" color touch screen (240 x 320 pixel, graphic LCD, resistive) Device Dimensions / Weight 209 x 98 x 52 mm; approx. 500 g Memory Capacity Up to 1,000 patients / tests Connectivity USB; Wireless 3G/LTE technology Power Consumption Max. 2 W Output (Headphone Socket) 5 Vpp, 32 Ω nominal impedance Output / Printing Label printer, PDF, or software Certification NHSRC Certified Device Yes ENNHSR Compatibility/Integration Yes Additional terms:  Payment: Government terms and conditions.  Warranty: 3 years’ warranty with 2 free on-site calibrations on device and accessories.  Delivery Terms: 30-45 days upon receipt of Notice to proceed (NTP) and Purchase Order (PO).  Delivery Address: Newborn Hearing Screening Reference Center, National Institutes of Health (NIH) Bldg. Room 105, University of the Philippines, Ermita, Manila Pre-bid Conference Date Time Venue 21/10/2026 1:30 PM The University of the Philippines-Manila, will hold a Pre-Bid Conference on 21 October 2026, the meeting will start at 01:30 p.m. and will follow the agenda for the day at the Procurement Management Office Conference Room at 2nd Floor Joaquin Gonzales Bui Created by MELODY JANE LISING ROJO Date Created 12/10/2026 The PhilGEPS team is not responsible for any typographical errors or misinformation presented in the system. PhilGEPS only displays information provided for by its clients, and any queries regarding the postings should be directed to the contact person/s of the concerned party. ©&nbsp2004-2026 DBM Procurement Service. All rights reserved. Help | Contact Us | Sitemap

This presentation only restructures stored source text. It does not add quantities, specifications, or delivery terms.

Extracted from the stored notice

Key requirements

These checks organize what BidAssistant found. “Known from stored extraction” describes the source record, not your company’s eligibility. Unknowns remain verification items.

Submission & process

Pre-Bid Conference

Known from stored extraction

Required in stored extraction

A specific pre-bid conference is identified in the procurement notice.

This means the requirement is present in the stored extraction. It does not mean your company satisfies it.

Stored timeline

Important dates

Published · Manila

Oct 13, 2026, 12:00 AM

Deadline · Manila

Nov 4, 2026, 11:30 AM

4 days left
First saved / captured

Oct 13, 2026, 4:00 AM

Last database update

Oct 13, 2026, 4:00 AM

These are stored timestamps. A missing pre-bid or other procurement date is not shown.

Source and provenance

Official source

Open the stored PhilGEPS source link

Original reference
13283335
Original stored title
Supply of Screening Device (General for ABR: Artifact Rejection: Weighted Averaging, Notch Filter (50/60 Hz, Self-Tuning))
Original buying agency
UNIVERSITY OF THE PHILIPPINES - MANILA
Stored status
active
View original stored description
Supply of Screening Device (General for ABR: Artifact Rejection: Weighted Averaging, Notch Filter (50/60 Hz, Self-Tuning)) AABR/ABR Screening Device with wireless 3G module technology General AABR/ABR Specifications Artifact Rejection Weighted averaging, notch filter (50/60 Hz, self-tuning) Residual Noise Calculation Collects noise energy per frame; calculates residual noise level (RMS in nV) Response Detection Auto peak-marker, template matching Normative Latencies For different age groups and transducer types Electrode Impedance Check Continuous monitoring; auto-start after impedance OK (R ≤ 4 kΩ, ΔR ≤ 2 kΩ) Sample Rate 48 kHz (stimulus); 16 kHz (response) Stimulus Parameters Stimulus Types Click (0.7–6 kHz), Chirp (broadband, 1–8 kHz), Tone Burst (500 Hz–4 kHz) Stimulus Polarity Condensation, rarefaction, alternating Stimulus Rate 10.1, 20.3, 30.7, 40.3, 69.9, 81.2, 90.4 Hz (default); user-defined 10–100 Hz Stimulus Levels 0 to max. 95 dB nHL (or transducer limits); Quick ABR screening: 35–55 dB eHL Masking Noise Offset -50 to +50 dB (white noise) Averages 1,000 to 20,000; step size: 1,000 Noise Stop Criterion 0, 10, 15, 20, 30, 40, 50, 60, 80 nV Automated Wave 5 Detection Minimum wave 5 criterion: 0, 20, 30, 40, 50, 70, 100, 150, 200 nVpp (optional) Plot Range (fixed) 0 to inter-stimulus interval + 1.5 ms (min. 10.5 ms; max. 15 ms) Physical / Interface Specifications Display 3.5" color touch screen (240 x 320 pixel, graphic LCD, resistive) Device Dimensions / Weight 209 x 98 x 52 mm; approx. 500 g Memory Capacity Up to 1,000 patients / tests Connectivity USB; Wireless 3G/LTE technology Power Consumption Max. 2 W Output (Headphone Socket) 5 Vpp, 32 Ω nominal impedance Output / Printing Label printer, PDF, or software Certification NHSRC Certified Device Yes ENNHSR Compatibility/Integration Yes Additional terms:  Payment: Government terms and conditions.  Warranty: 3 years’ warranty with 2 free on-site calibrations on device and accessories.  Delivery Terms: 30-45 days upon receipt of Notice to proceed (NTP) and Purchase Order (PO).  Delivery Address: Newborn Hearing Screening Reference Center, National Institutes of Health (NIH) Bldg. Room 105, University of the Philippines, Ermita, Manila Pre-bid Conference Date Time Venue 21/10/2026 1:30 PM The University of the Philippines-Manila, will hold a Pre-Bid Conference on 21 October 2026, the meeting will start at 01:30 p.m. and will follow the agenda for the day at the Procurement Management Office Conference Room at 2nd Floor Joaquin Gonzales Bui Created by MELODY JANE LISING ROJO Date Created 12/10/2026 The PhilGEPS team is not responsible for any typographical errors or misinformation presented in the system. PhilGEPS only displays information provided for by its clients, and any queries regarding the postings should be directed to the contact person/s of the concerned party. ©&nbsp2004-2026 DBM Procurement Service. All rights reserved. Help | Contact Us | Sitemap

Freshness: First saved / captured Oct 13, 2026, 4:00 AM; last database update Oct 13, 2026, 4:00 AM.

New notices are collected periodically, but this service does not routinely refresh already-known notices. Stored dates and status may miss deadline extensions, cancellations, or amendments. Always check the latest official PhilGEPS notice. First-saved and last-update times describe our stored record, not a fresh check of the official notice.

BidAssistant PH is an independent discovery and screening aid, not PhilGEPS or a procuring agency.